Radiant Presents a Method for Improving Accuracy in Pixel-Level Measurement

Radiant Vision Systems, a leading provider of photometric imaging solutions for light and display measurement, announces that it will present a technical paper during the 2020 Display Week Symposium taking place online from August 3-7.

The Symposium is one of several events planned over the course of Display Week 2020 including a virtual technical program and exhibition organized by The Society for Information Display (SID). Doug Kreysar, Chief Executive Officer at Radiant Vision Systems, will present the company’s paper titled “Fractional Pixel Method for Improved Pixel-Level Measurement and Correction (Demura) of High-Resolution Displays” authored by Kreysar, Gary R. Pedeville (Senior Principal Engineer), and Joshua H. Rouse (Senior Optical Software Engineer III) from Radiant. The presentation will be available for registered attendees to view online in Session 71: Spatial Uniformity beginning Thursday, August 6.

“Display resolution and pixel density continue to increase dramatically, and so does the importance of measuring displays from the pixel level,” says Kreysar. “Technologies like OLED, mini-, and microLED are illuminated by their emissive pixels and subpixels, which can vary in output. This variation results in nonuniform brightness and color across the display, making measurement and correction processes a critical part of quality control. Measuring the characteristics of individual display pixels, however, has become more challenging for image-based measurement technology, which must apply several sensor pixels per display pixel for accurate measurement. A new fractional-sensor-pixel measurement method was developed by Radiant to improve the accuracy of image-based measurements specifically for ‘demura’ or pixel uniformity correction applications. This method enables highly flexible display pixel registration to ensure accurate calculation of display pixel correction factors to improve display uniformity.”

An online presentation of Radiant’s technical paper during the virtual Display Week Symposium will introduce the company’s fractional pixel method and provide data demonstrating the method's accuracy for pixel-level luminance measurement over traditional “whole pixel” methods. The results will show that luminance data obtained using imaging systems with limited sensor resolution (achieving as few as 3 x 3 image sensor pixels per display pixel)—when a fractional pixel method is applied—provide a very close match to luminance data obtained using an extremely high-resolution imaging system (achieving as many as 30 x 30 image sensor pixels per display pixel). Without a fractional pixel approach, pixel-level luminance measurements obtained using available imaging systems may have significant inaccuracies. These inaccuracies can impact correction processes, resulting in noticeably poor visual quality in “corrected” displays.

Presenting the paper on behalf of Radiant Vision Systems, CEO Doug Kreysar has a background in engineering, physics, and management, having led multiple departments at Radiant since joining the company in 2000. Formerly the company’s Chief Solutions Officer, Kreysar has overseen the development of Radiant’s optical technologies for light and color measurement across production applications worldwide. Kreysar earned a B.S. in Physics from Vanderbilt University and an M.S. in Applied Physics from the University of Michigan, Ann Arbor. He is the author of multiple technical papers and a regular speaker for organizations including the Society for Information Display (SID). He has received an Excellence in Oral Presentation Award from the Society of Automotive Engineers (SAE) and holds eight U.S. patents.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Radiant Vision Systems. (2020, July 17). Radiant Presents a Method for Improving Accuracy in Pixel-Level Measurement. AZoOptics. Retrieved on November 24, 2024 from https://www.azooptics.com/News.aspx?newsID=25154.

  • MLA

    Radiant Vision Systems. "Radiant Presents a Method for Improving Accuracy in Pixel-Level Measurement". AZoOptics. 24 November 2024. <https://www.azooptics.com/News.aspx?newsID=25154>.

  • Chicago

    Radiant Vision Systems. "Radiant Presents a Method for Improving Accuracy in Pixel-Level Measurement". AZoOptics. https://www.azooptics.com/News.aspx?newsID=25154. (accessed November 24, 2024).

  • Harvard

    Radiant Vision Systems. 2020. Radiant Presents a Method for Improving Accuracy in Pixel-Level Measurement. AZoOptics, viewed 24 November 2024, https://www.azooptics.com/News.aspx?newsID=25154.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.